white banner donaldson

Filter Minder® Visual / Electrical Switches

Air Filter Restriction Monitoring Indicator / Switch

Single Position & Signal Indication / Threaded Mount

 

How It Works

The Filter Minder® Single Position Switch Indicator is a combination single position indicator and switch. The window turns red when the maximum recommended air filter restriction has been reached and a signal is sent to the filter warning light on the dash or to the engine computer to record as a diagnostics fault. The warning light locks on until the indicator is reset.

The Filter Minder® should be reset whenever the service indicator is checked to determine air filter restriction or when a new air filter is installed. Push the reset button at the end of the service indicator, and the position indicator will return to zero.

Read more: Filter Minder® Single Position Switch Indicator

How the Fuel Filter Restriction Monitoring Switch Works

The Filter Minder® Non-Locking Fuel Switch continuously monitors the fuel filter and tells when the filter is restricted. Triggers fuel filter warning light via the engine computer or directly to the warning light. For use on diesel suction-side fuel filters.

Read more: Filter Minder® Non-Locking Fuel Switch

Air Filter Restriction Monitoring Switch

Triggers Air Filter Warning Light / Non-Locking

 

How It Works

The Filter Minder® Non-Locking Air Switch continuously monitors the engine air filter and tells when filter is restricted. Triggers air filter warning light via the engine computer or directly to the warning light. Used for air filter monitoring on diesel, gas, and alternate fuel engines, as well as other applications where low vacuum/pressure monitoring is required.


Filter Minder® Non-Locking Air Switch

Series

196389 (Packard Metri-Pack 150 series)
196351 (Ampseal 16)

Mounting

Mounts directly to air cleaner or air induction piping.  See Accessories / Related Products for adaptor fittings and brackets for remote mounting.

Specifications

  • Vacuum or Pressure Monitoring
  • Vacuum Ranges: minimum 3" H20 (0.75 kPa) ± 40% @ 23°C to 50" H20 (12.4 kPa) maximum ±10% @ 23°C
  • Pressure Ranges:
    • Lowest set point - 0.11 PSI (0.75 kPa) ±20% @ 23°C.
    • Highest set point - 2.0 PSI (14 kPa) ±10% @ 23°C
  • Operating Temperature: -40°F to +250°F (-40°C to +121°C)
  • Material: Nylon
  • Mounting Port Connections: 3/8-24 Straight Thread O-Ring, M10x1 Straight Thread O-Ring or 1/8-27 NPT
  • Switch: Normally open or closed available

Dimensions

  • Length: 2.1" (53 mm)
  • Diameter: 2.0" (50 mm)

Air Filter Restriction Monitoring Gauge / Switch

Graduated / Electrical Indication / Threaded Mount

How It Works

A combination graduated indicator and switch, the Filter Minder® Graduated Switch features a position indicator that progressively fills the window as air filter restriction increases, locking at the highest restriction. When it reaches the red zone, or highest recommended restriction, it sends a signal to the filter warning light on the dash or to the engine computer to record as a diagnostics fault. The warning light locks on until the indicator is reset.

The Filter Minder® should be reset whenever the service indicator is checked to determine air filter restriction or when a new air filter is installed. Push the reset button at the end of the service indicator, and the position indicator will return to zero.


Filter Minder® Graduated Switch Indicator

Series

135578 (1/8-27 NPT)
136578 (3/8-24 Straight Thread O-Ring)
137578 (M10x1 Straight Thread )-Ring)

Mounting

Mounts directly to air cleaner or air induction piping.  Adaptor fittings are available.  Brackets for remote mounting are also available.  See Accessories / Related Products.

Specifications

  • Vacuum Indicator
  • Locking Type
  • Operating Temperature: -40 to +250°F (-40 to +121°C)
  • Switch Activation Point: 8" water vacuum (2kPa) minimum to 35" water vacuum (8.7kPa) maximum. Contact the company for special calibrations.
  • Accuracy: ±10% at switch activation
  • Material: Polycarbonate housing
  • Normally open or closed switches with precious metal contacts
  • Molded in Packard Metri-Pak 150 Series
  • Severe Dust Filter also available

 Dimensions

  • Length: 3.1" (79mm)
  • Diameter: 2.0" (50mm)  [64 mmwith connector]