Installing a Threaded Mount Air Filter Restriction Gauge

Filter Minder® - The Global Leader of air and fluid filtration monitoring solutions, offering:

Threaded Mount Air Filter Restriction Indicator / Gauge

-  Low-Dollar Cost, High-Value Add
-  Superior Quality and Performance
-  Solutions-Driven Portfolio
-  Industry's Broadest Product Line
-  Highest Level Customer Support
-  Award Winning On-Time Delivery

 

Got a problem?  Challenge Us.  We will find a solution.

Installation - Step One

  • Default
  • Title
  • Date
  • Filter Minder® Product Portfolio
  • The air filter restriction gauge should be installed on the air filter housing (clean air side).

    " data-mosaic-order-date="">
    Step 1A

    The air filter restriction gauge should be installed on the air filter housing (clean air side).

  • Select the location for the gauge and check hood clearance.

    " data-mosaic-order-date="">
    Step 1B

    Select the location for the gauge and check hood clearance.

  • The gauge may be mounted vertically or horizontally.

    " data-mosaic-order-date="">
    Step 1C

    The gauge may be mounted vertically or horizontally.

Installation - Step Two

  • Default
  • Title
  • Date
  • Filter Minder® Product Portfolio
  • Open the air cleaner housing and drill an 11/16" hole.

    " data-mosaic-order-date="">
    Step 2A

    Open the air cleaner housing and drill an 11/16" hole.

  • IMPORTANT: Do not let shavings fall into the intake manifold.

    " data-mosaic-order-date="">
    Step 2B

    IMPORTANT: Do not let shavings fall into the intake manifold.

  • A spade bit or similar cutting implement works well for plastic housings.

    " data-mosaic-order-date="">
    Step 2C

    A spade bit or similar cutting implement works well for plastic housings.

Installation - Step Three

  • Default
  • Title
  • Date
  • Filter Minder® Product Portfolio
  • Press the rubber grommet into the 11/16" hole (drilled in Step Two) until it seats into the proper position, locking in place.

    " data-mosaic-order-date="">
    Step 3A

    Press the rubber grommet into the 11/16" hole (drilled in Step Two) until it seats into the proper position, locking in place.

  • Push the gauge into the rubber grommet until fully seated. If needed, use water or a mild soap solution to help insertion.

    " data-mosaic-order-date="">
    Step 3B

    Push the gauge into the rubber grommet until fully seated. If needed, use water or a mild soap solution to help insertion.

  • Do not use solvents, oil, or other petroleum based products, as they can crack the clear housing of the Filter Minder®.

    " data-mosaic-order-date="">
    Step 3C

    Do not use solvents, oil, or other petroleum based products, as they can crack the clear housing of the Filter Minder®.

Installation - Step Four

  • Default
  • Title
  • Date
  • Filter Minder® Product Portfolio
  • Close the air cleaner cover, again taking care to prevent any shavings from entering the manifold. Ensure the Filter Minder® is securely seated.

    " data-mosaic-order-date="">
    Step 4A

    Close the air cleaner cover, again taking care to prevent any shavings from entering the manifold. Ensure the Filter Minder® is securely seated.

  • Unclamp the entrance to the air cleaner port and, with the engine running, slowly close off the opening.

    " data-mosaic-order-date="">
    Step 4B

    Unclamp the entrance to the air cleaner port and, with the engine running, slowly close off the opening.

  • Watch the Filter Minder® gauge ratchet up to indicate restriction. Push the reset button and you're done.

    " data-mosaic-order-date="">
    Step 4C

    Watch the Filter Minder® gauge ratchet up to indicate restriction. Push the reset button and you're done.